EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com
1.76 E11011
Ex-Housing Zone 1/21
for screw terminals
Design GK...
Dimensions
ID-No. Z01168 Z01169 Z01170 Z01171 Z01172
Type GKE 60 GKE 100 GKI 60 GKI 100 GKEI 100
Amount of terminals 4 8 4 8 4 Ex e + 4 Ex ia
Dimensions [mm] 58x64 98x64 58x64 98x64 98x64
Electric circuits increased safety intrinsically safe
intrinsically safe + increased safety
Ex marking II 2G Ex e II T6 II 2G Ex ia IIC T6 II 2G Ex e [ia] IIC T6
II 2D IP 65 T 75 °C II 2D IP 65 T 75 °C II 2D IP 65 T 75 °C
Certificate No. BVS 05 ATEX E022 X
Ambient temperature [°C] 20...+70
für temperature classes [°C] T4, T5, T6 : 70
Rated voltage [V] 275
Rated current [A] 2
Cross section wires single wire 0.5...2.5 mm
2
multistrand 0.5...1.5 mm
2
Cable diameter [mm] 4...8
Housing material aIuminium
Protection [EN 60529] IP 65
Connection terminal space
The housing for screw terminals type GK... is designed for the connection of intrinsically safe and / or non-intrinsically
safe circuits in explosion-hazardous areas of category 2 (Zone 1 and 21).
Series GK...
II 2G Ex e II T6
II 2G Ex ia IIC T6
II 2G Ex e [ia] IIC T6
II 2D IP 65 T 75 °C
For the connection of supply
and signal lines in Zone 1/21
Zone 0 / 20 Zone 1/ 21
sensor
GKI...
Zone 1/ 21Zone 1/ 21
amplifier
GKE...
sensor circuit
intrinsically safe
supply circuit
increased safety
amplifier
SS 400 Ex/
SF3
GKI 60
GKE 100
output
increased safety
64
H = 36
58
19
64
H = 36
98
19